All about water...

Absolute Filtration Technology Standard
  • 2025-07-09

Absolute Filtration Technology Standard

Absolute Filtration Technology Standard


Definition and Classification Standards

Absolute filtration refers to the retention rate of the filter element for target particle size being ≥99.9% (β value ≥1000), with the following core performance parameters:


Precision Identification:


Nominal aperture (μm) Actual retention particle size (μm) Test standard

0.1 ≥0.13 ASTM F838-05

0.22 ≥0.30 ISO 16890-2016

5.0 ≥5.3 GB/T 18853-2015

Efficiency verification:


Latex bead challenge test: >99.98% (5μm particles)


Bacterial retention rate: >7-log (Pseudomonas aeruginosa)


Key application scenarios


Category Target Contaminant Precision Requirement Typical Filter Material

Medical Dialysis Endotoxin 0.1μm Hydrophilic PTFE Membrane

Drinking Water Safety Cryptosporidium Oocysts 1.0μm Meltblown Polypropylene

Semiconductor Ultra-pure Water Colloidal Silicon 0.03μm Ceramic Membrane

Industrial Implementation Plan

■ Structural Design


Graduated Density Filter Layer: Surface 5μm/Deep Layer 0.5μm (Anti-Surface Clogging)


Membrane Folding Technology: Effective Area Increased by 300% (Compared to Flat Membrane)

■ Operating Parameters


Design Filter Rate: ≤10m³/㎡·h (Ensures Retention Rate)


Maximum Pressure Difference: 0.2MPa (Prevents Structural Deformation)


Selection Specification


Microbial Control


Sterilization Requirements: Select 0.22μm sterilizing-grade filter core (FDA 21 CFR 210.3)


Virus Retention: Requires a composite 0.01μm ultrafiltration membrane (molecular weight cut-off 100kDa)


Chemical Compatibility


Filter material pH tolerance range Applicable medium

Nylon 66 4-10 Organic solvents

Polyethersulfone1-13Strong acid/alkali systems


Copyright 2025 All Right Reserved. Hebei Fupeng Environmental Protection Technology Group Co., LTD